Technical laminates – tubes and rods
PAPER PHENOLIC TUBES
Tubes type acc. to DIN 7735: Hp 2065
The tubes made from cellulose paper as a basis and phenolformaldehyde resin as a binder. This tubes are used like insulating and constructive material for various electrical equipment construction.
Available dimensions: The tubes are produced from inside diameter 5,2 mm.
The wall thickness is from 2 mm.
The tube length is 1050 mm.
Machining: The tubes are machined by cutting, milling, drilling, turning.
|
Properties |
Unit |
Value |
|
Density |
g/cm³ |
1,05 1,30 |
|
Flexure strength, min. |
MPa |
75 |
|
Pressure strength, min. |
MPa |
40 |
|
Insulation resistance after 96 hours in water 85%, min. |
Ω |
5.108 |
|
Breakdown voltage in oil pallarel to layers by 90°C for 20 mm, min. |
kV |
25 |
|
Electrical strenght in oil, pallarel to layers by 90°C, min. |
kV |
10 |
COTTON PHENOLIC TUBES
Tubes type acc. to DIN 7735: Hgw 2085
The cotton phenolic tubes are made from cotton fabric as a basis and phenolformaldehyde resin as a binder. This tubes are suitable for production of chambers of expansionary small-oil schwiters, case bearing etc.
Available diameters: The tubes are produced from inside diameter 5,2 mm.
The wall thickness is from 2 mm.
The length is 650 mm for inside diameter 5,2 mm to 25 mm.
The length is 1350 mm for inside diameter 25 mm and more.
Machining: The tubes are machined by cutting, turning, drilling and milling.
|
Properties |
Unit |
Value |
|
Density |
g/cm³ |
1,15 1,42 |
|
Flexure strength, min. |
MPa |
80 |
|
Pressure strength, min. |
MPa |
40 |
|
Insulation resistance after 96 hours in water 85%, min. |
Ω |
1,0.107 |
|
Breakdown voltage in oil pallarel to layers by 90°C for 20 mm, min. |
kV |
15 |
|
Electrical strenght in oil, pallarel to layers by 90°C, min. |
KV.mm-1 |
2 |
GLASS EPOXY TUBES G11 – Hgw 2375
Tubes type acc. to DIN 7735: Hgw 2375
The glass epoxy tubes are made from modified glass fabric as a basis and epoxy resin as a binder. This tubes have very good mechanical and electrical properties at high huminidy and mechanical strenght at higher temperatures.
Available dimenisons: The tubes are produced from inside diameter 5,2 mm.
The wall thickness is from 2 mm.
The tube length is 1050 mm.
Machining: The tubes are machined by cutting, turning, drilling and milling
|
Properties |
Unit |
Value
|
|
Density |
g/cm³ |
1,85 |
|
Flexure strenght, min. |
MPa |
280 |
|
Pressure strengtht, min. |
MPa |
150 |
|
Insulation resistance after 96 hours in water 85%, min. |
Ω |
1,0.108 |
|
Breakdown voltage in oil pallarel to layers by 90°C for 20 mm, min. |
kV |
20 |
|
Electrical strenght in oil, pallarel to layers by 90°C, min. |
KV.mm-1 |
10 |
COTTON PHENOLIC RODS
Norm: Hgw 2088
Rolled cotton phenolic rods are made from cotton fabric and phenolformaldehyde resin as a binder. There are suitable as a constructive material for production of various components (mechanically and electrically stressed).
Available diameters: The rods are produced from diamter 6 mm to 200 mm.
The tube length is 1000 mm.
| Properties | Unit | Values |
| Flexure strenght, min. | MPa | 100 |
| Pressure strenght, min. | MPa | 100 |
| Tension strenght, min. | MPa | 50 |
| Insulation resistance, min. | Ohm | 107 |
| Temperature class | E | |
| Breakdown voltage in oil pallarel to layers by 90 oC diam. 20 mm (min.) | kV | 10 |
| Density | kg.m-3 | 1300-1420 |
GLASS EPOXY TUBES G11 – Hgw 2375.4
The glass epoxy tubes are made from modified glass fabric as a basis and epoxy resin as a binder. This tubes have very good mechanical and electrical properties at high huminidy and mechanical strenght at higher temperatures.
Available dimenisons: The tubes are produced from inside diameter 5,2 mm.
The wall thickness is from 2 mm.
The tube length is 1050 mm.
Machining: The tubes are machined by cutting, turning, drilling and milling
|
Properties |
Unit |
Value |
|
Density |
g/cm³ |
1,7-1,9 |
|
Flexure strenght, min. |
MPa |
300 |
|
Pressure strengtht, min. |
MPa |
175 |
|
Insulation resistance after 24 hours in water min. |
Ω |
1,0.103 |
|
Breakdown voltage in oil pallarel to layers by 90°C for 20 mm, min.
|
KV/mm |
40 40 |
|
Electrical strenght in oil, pallarel to layers by 90°C, min.
|
KV.mm-1 |
11,6 7,7 |
|
Water absorption, max. |
mg/cm² |
1,5 |
|
Thermal endurance |
T.I. |
155 |